• Robert Dansertlaan 250, 1702 Groot-Bijgaarden, Belgium

Cycloaliphatische steunisolatoren voor buiten

CO – Cycloalifatische steunisolatoren voor buiten – Catalogusblad
Download

Cycloaliphatic epoxy resin material

I3333 - 3.6kV Cycloalifatische isolatoren voor gebruik buiten

Cycloaliphatic epoxy standoff insulators 3,6 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2a - Rated Power Frequency Withstand Voltage, dry (50 Hz, 1 min)
2b - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK

7,2 kV Cycloalifatische isolatoren voor buitengebruik

Cycloaliphatic epoxy standoff insulators 7,2 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2a - Rated Power Frequency Withstand Voltage, dry (50 Hz, 1 min)
2b - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK

12 kV Cycloalifatische isolatoren voor buitengebruik

Cycloaliphatic epoxy standoff insulators 12 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2a - Rated Power Frequency Withstand Voltage, dry (50 Hz, 1 min)
2b - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK

24 kV Cycloalifatische isolatoren voor buitengebruik

Cycloaliphatic epoxy standoff insulators 24 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2 - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK

36 kV Cycloalifatische isolatoren voor buitengebruik

Cycloaliphatic epoxy standoff insulators 36 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2 - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK

36/52 kV Cycloalifatische isolatoren voor buitengebruik

Cycloaliphatic epoxy standoff insulators 36/52 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2 - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK

24/36 kV Cycloalifatische isolatoren voor buitengebruik

Cycloaliphatic epoxy standoff insulators 24/36 kV for outdoor use

Rated values according to IEC 60273 - Tests according to IEC 60660
1 - Rated Highest voltage for equipment (Um)
2 - Rated Power Frequency Withstand Voltage, wet (50 Hz, 1 min)
3 - Rated Lightning impulse withstand (1.2/50 μs)
cr - Creepage distance
N - Flexion resistance
Recommended tightening torque for epoxy insulators
Thread --> (Nm)
M6 --> 7 Nm
M8 --> 10 Nm
M10 --> 30 Nm
M12 --> 50 Nm
M16 --> 120 Nm
M20 --> 200 Nm
M24 --> 250 Nm
(*) IN STOCK