Motor bushings
Ceramic – Motor bushings
Motor bushings
Download motor bushing catalog – catalog sheet
DownloadCeramic / porcelain material
Ceramic group | Ceramic group | Ceramic group | Ceramic group | |||||
---|---|---|---|---|---|---|---|---|
Sub-Group | C-110 | C-120 | C-130 | C-221 | ||||
Silicious Porcelain | Aluminous porcelain Standard strength | Aluminous porcelain High strength | Steatite low/loss angle |
|||||
Properties | Properties | Properties | Symbols | Units | AL2O3 <30% | AL2O3 30-50% | AL2O3 >50% | |
Apparent prosity (open) | max. | max. | Pa | Volume % | 0.0 | 0.0 | 0.0 | 0.0 |
Bulk density | min. | min. | δa | g/cm3 | 2,2 | 2,3 | 2,5 | 2,7 |
Flexural strength | min. | unglazed | Rf | N/mm2 | 50 | 90 | 140 | 140 |
min. | glazed | Rf | N/mm2 | 60 | 110 | 160 | - | |
Modulus of elasticity | min | E | GPa | 60 | 70 | 100 | 100 | |
Mean coefficient linear expansion | α 20-100°C | 10-6K-1 | 3-6 | 3-6 | 4-7 | 6-8 | ||
α 20-300°C | 10-6K-1 | 3-6 | 3-6 | 5-7 | 7-9 | |||
α 20-600°C | 10-6K-1 | 4-7 | 5-7 | 5-7 | 8-9 | |||
Specific heat capacity | 20°-100°C | cp | J/kgK | 750÷900 | 750÷900 | 750÷900 | 790÷920 | |
Thermal conductivity | 20°-100°C | λ | W/mK | 1÷2,5 | 1,2÷2,6 | 1,5÷4,0 | 2,3÷2,8 | |
Resistance to thermal shock | min. | Δt | K | 150 | 150 | 150 | 100 | |
Electric strength | min. | Ed | kV/mm | 20 | 20 | 20 | 20 | |
Withstand voltage | min. | U | kV | 30 | 30 | 30 | 30 | |
Relative permittivity | 48÷62 Hz | εr | 6÷7 | 6÷7 | 6÷7,5 | 6 | ||
Dissipational 20°C | max. | 48÷62 Hz | tanδ | 10-3 | 25 | 25 | 30 | 1,5 |
max. | 1 kHz | tanδ | 10-3 | - | - | - | - | |
max. | 1 MHz | tanδ | 10-3 | 12 | 12 | 15 | 1,2 | |
Volume resistivity in terms of temperature | min. | 20°C | ρv | Ωcm | 1013 | 1013 | 1013 | 1012 |
min. | 200°C | ρv | Ωcm | 108 | 108 | 108 | 1011 | |
min. | 600°C | ρv | Ωcm | 104 | 104 | 104 | 107 | |
Temperature corresponding to a volume resistivity | min. | 100 MΩcm | tK100 | °C | 200 | 200 | 200 | 500 |
min. | 1 MΩcm | tK1 | °C | 350 | 350 | 350 | 800 |
Sulphur cement = excellent mechanical performances and max use temperature 90°C - Reduced assembly time
Portland cement = max use temperature 200°C - Drying time in mould is longer
Ceramic Terminal motor bushing
Ceramic terminal motor bushing
Ref. | a | b | c | d1 | d2 | d3 | d4 | d5 | d6 | d7 | d8 | d9 | h1 | h2 | h3 | r1 | r2 | r3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | ||||||||
1/3/200 | 17,5 ±1 | 5 ±0,6 | 18 | 50 ±3 | 38 | 41 | 32 | 24 ±1,5 | 26 | 62 ±3 | 70 ±3 | 11,5 ±1 | 5 | 1 | 8 | 2 | 1,5 | 4 |
1/3/400 | 26 ±1,5 | 6,5 ±0,6 | 20 | 60 ±3 | 48 | 51 | 42 | 34 ±1,5 | 36 | 74 ±3 | 82 ±3 | 18 ±1,5 | 5 | 1 | 8 | 2 | 2 | 5 |
1/6/200 | 17,5 ±1 | 5 ±0,6 | 20 | 60 ±3 | 42 | 48 | 32 | 24 ±1,5 | 27 | 74 ±3 | 82 ±3 | 11,5 ±1 | 6 | 2 | 10 | 2,5 | 1,5 | 5 |
1/6/400 | 26 ±1,5 | 6,5 ±0,6 | 25 | 70 ±3 | 52 | 58 | 42 | 34 ±1,5 | 37 | 86 ±3 | 95 ±4 | 18 ±1,5 | 6 | 2 | 10 | 2,5 | 2 | 6 |
2 - Nominal Voltage (Un) - 20 MHz
3 - Rated Power Frequency Withstand Voltage, dry (50 Hz, 1 min)
H - Height insulating part
H2 - Usable Height support
H3 - Height with 1 male rod